Electrical PVC Cable Testing as per IS:694, IS:1554 and IS:8783
Sl. No. | Test/Parameter | Range of Testing | Standard equipment used |
---|---|---|---|
1. |
Conductor Resistance test |
Resistance: 10m Ohm to 1 Ohm |
Industrial Kelvin Bridge-Vaisishika-9404
|
2. |
Tensile test |
Force: 10N to 200N 400N to 10000 N |
Tensile Testing Machines-KMI-1.3D & 1.4F |
3. |
Insulation Resistance test |
Resistance: 10 k Ohm to 975 G Ohm |
Ultra High Resistance Meter-Advantest-R8340 Temperature Controlled Water Bath |
4. |
High Voltage Test |
1 kV to 10 kV AC |
AC High Voltage Test Set-RE Electrostatic Voltmeter, EIS – ESH 28X |
5. |
Thickness of PVC Insulation & PVC sheath |
Thickness: 0.5mm to 25 mm |
Profile Projector-Dynascan
|
6. |
Annealing Test |
- |
- |
7. |
Thermal Aging |
- |
Temperature Controlled Heating Oven |