Measurement Capability :
Parameter/Test | Range/Accuracy/Specifications |
---|---|
Emission, Immunity and Harmonics | CISPR 22 & CISPR 24, IEC61000-3-2, EN 55022 & EN 55024 |
Conducted Emission | CISPR, EN, BS,IEC, AS,VDE,IS,TEC |
Radiated Emission | CISPR, EN, BS,IEC, AS,VDE,IS,TEC |
Harmonics Emission | EN,BS EN,IEC,IS |
Flicker Emission | IEC,EN,BS EN ,IS |
Radiated Power | CISPR,EN,BSEN,IS |
ESD Test | IEC, EN,BSEN, IS |
Radiated Immunity Test | IEC, EN,BSEN, IS |
Burst Test /Electric fast Transients | IEC, EN,BSEN, IS |
Surge Immunity | IEC, EN,BSEN, IS |
Conducted (RF) Immunity Test | IEC, EN,BSEN, IS |
Power Freq. Magnetic Immunity Test | IEC, EN,BSEN, IS |
Damped Pulsed Magnetic Immunity Test | IEC, EN,BSEN, IS |
Voltage Dip & Interruption Test | IEC, EN,BSEN, IS |
Damped Oscillatory & ring wave Immunity Test | IEC, EN,BSEN, IS |
Site Survey | E and H Field |
|
List Of Major Facility
Facility / Equipment / Tools | Make and Model |
---|---|
EMI Test Receiver | Rohde & Schwartz, ESCI |
LISN | Rohde & Schwartz ENV4200 3 Phase, 200 A |
LISN | AFJ LT-32 3 Phase 32 Amp |
LISN | Scientific Mestek , SMLIN25-2, Single Phase 25 A |
Semi Anechoic |Chamber | ETS Lindgren USA 3 Meter |
Antenna Mast | ETS Lindgren &EMCO |
Turn Table | ETS Lindgren& EMCO |
Dual Channel Controller | ETS Lindgren |
Amplifier 250W | AR, 250W upto 1 GHz |
Amplifier 25 W | Amplifier Research |
Antenna Bi-conical, Log periodic | EMCO |
RF Field Probe | NARDA NBM-520, EF1891 and EF0391 |
RF Field Probe | Dare CTR1009B |
E & H meter | Holladay HI 3604 |
Current Probes | Rohde & Schwartz EZ-17 |
Absorbing Clamps | Rohde & Schwartz MDS-21 |
Antennae Bi-conical & Log Periodic | EMCO |
Antennae – Loop , Rod, Horn ,Adj. Dipole | EMCO |
Antenna Bi-Log | Frankonia BA600 |
Harmonic & Flicker Test system | Pacific upto 300V,16 A Single Phase |
Immunity Test Facilities | : |
Impulse (Surge) Test Generator | EMC Partner MIG 1206 Upto 12 kV |
ESD Simulator | EM Test ESD 30C |
ESD Simulator | Schaffner NSG432 |
EFT/Burst Simulator | TESEQ NSG 3040 with single phase CDN upto 16 A |
Three Phase CDN for EFT | TESEQ CDN 3083-B100 |
Capacitive Coupling Clamp | TESEQ CDN 3425 |
EFT/Burst Simulator | EM Test EFT 800 with single phase CDN upto 16 A |
Power Frequency Magnetic Field Loop (1m x 1m) | EM Test MC2630 and MC26100 From 1 A/m to 1000A/m |
1 MHZ/100 kHz Damped Sinusoidal with CDN | HAFFELEY , PIM 110,P SURGE 8000, PID 126 A |
Voltage Dip & Interference Simulator | Pacific TMX-125 |
Signal Generator | Rohde & Schwartz SML-01 |
Signal Generator | Rohde & Schwartz SML-03 |
Coupling-Decoupling Network | EM test, (M3 M5) |
EM Clamp | EM Test |
Reference Radiator | ETS Lindgren |
Three phase portable reference meter | KIGG K15 |
Major Products Tested / Projects Done |
---|
Testing of - Domestic ( Household ) Appliances |
Industrial Products |
Power Electronics Equipment |
Information Technology & Telecommunication Products |
In-Vitro Medical Products |
Please refer the certificate no TC-5435 for NABL Accreditation / scope details |